JJG 959-2001 光时域反射计
JJG 959-2001 Optical Time Domain Reflectometer
基本信息
发布历史
-
2001年02月
-
2024年02月
研制信息
- 起草单位:
- 中国计量科学研究院
- 起草人:
- 方毓文
- 出版信息:
- 页数:21页 | 字数:27 千字 | 开本: 大16开
内容描述
utfG(
中华人民共和国国家计量检定规程
JJG959-2001
光时域反射计
OpticalTimeDomainReflectometer
2001一02一01发布2001一05一01实施
国家质量技术监督局发布
JJG959-2001
光时域反射计(O下DR)
产~0.~0.口.补~0.口.0.0.0·。·0.飞
己︺叭.,八
叭.︺启.
检定规程乙
,成-,
.︺叭.
}JJG959-2001
VerificationRegulationofOptical口.J叭
TimeDomainReflectometer
本规程经国家质量技术监督局于2001年02月01日批准,并自2001
年05月01日起施行。
归口单位:全国几何量长度计量技术委员会
起草单位:中国计量科学研究院
本规程委托全国几何量长度计量技术委员会负责解释
标准分享网免费下载
JJG959-2001
本规程主要起草人:
方毓文(中国计量科学研究院)
参加起草人:
李天初(中国计量科学研究院)
王民明(中国计量科学研究院)
李雪松(中国计量科学研究院)
张诚平(中国计量科学研究院)
JJG959-2001
目录
1范围····························································,·····························……(1)
2术语··························································································……(1)
3概述··························································································……(2)
4计量性能要求··············································································……(3)
4.1输出光中心波长······································································……(3)
4.2距离测量扩展不确定度·······························································……(3)
4.3损耗测量扩展不确定度·······························································……(3)
4.4位置偏差·················································································……(3)
4.5动态范围·················································································……(3)
4.6“衰减盲区”长度(3)
4.7“事件盲区”长度(3)
5通用技术要求··············································································……(3)
5.1标志·······················································································……(3)
5.2技术资料···························。·····················································……(3)
5.3外观·······················································································……(4)
5.4功能键····················································································……(4)
6计量器具控制···································································……‘’‘’‘’‘’.‘’(4)
6.1首次检定和后续检定·······················································……‘·‘.“““(4)
6.2检定条件·················································································……(4)
6.3检定项目和检定方法··················································……‘·‘”““““‘”(5)
6.4检定结果的处理·。··········································……”””””””””“’“’““(16)
6.5检定周期。(16)
附录A光时域反射计检定记录基本格式·············································……(17)
标准分享网免费下载
JJG959-2001
光时域反射计检定规程
范围
本规程适用于光时域反射计(OTDR)的首次检定和后续检定。
2术语
2.1中心波长(x中心)
用nm表示的光源加权平均真空波长。
对连续光谱,中心波长定义为
(1)
对分离光谱
习P':l;
*中J。一}'Pi
(2)
式中:几—光源的谱功率密度;
A;—分立波长;
尸—波长为A,激光模的功率。
2.2参考距离(D,er)
借助于准确度比)〔TDR高的计量标准或测量仪器确定的光纤特征点之间的距离(m).
2.3距离标尺系数(SL)
OTDR平均显示距离除以相应的参考距离
(D.a,)
SL(3)
Drer
式中:D,,,,OTDR测量参考距离的显示平均值。
2.4参考位置(L-f)
借助于准确度比OTDR高的计量标准或测量仪器确定的OTDR前面板到光纤一个
特征点之间的距离(m)a
2.5位置偏差△Lo
OTDR测量参考位置特征点的显示值减去参考位置(m)(近似等于OTDR输出接
头在OTDR距离标尺的显示位置。对一个理想的OTDR,此项应为零)。
.TJG959-2001
AL,=L.1d:一(4)
式中:L,,,-OTDR测量参考位置的显示值。
2.6参考损耗(Ase,)
借助于不直接利用OTDR功率标尺的方法精确标定的一个光纤元件的损耗(dB)o
2.7损耗标尺系数(SA)
显示损耗与参考损耗之比(dB/dB)
A一汽ef-劝
--
推荐标准
- YS/T 536.3-2009 铋化学分析方法 锑量的测定 孔雀绿分光光度法 2009-12-04
- YS/T 536.6-2009 铋化学分析方法 铅量的测定 电热原子吸收光谱法 2009-12-04
- YS/T 536.2-2009 铋化学分析方法 铁量的测定 电热原子吸收光谱法 2009-12-04
- YS/T 539.10-2009 镍基合金粉化学分析方法 第10部分:钼量的测定 硫氰酸盐分光光度法 2009-12-04
- YS/T 536.13-2009 铋化学分析方法 镉量的测定 电热原子吸收光谱法 2009-12-04
- YS/T 536.5-2009 铋化学分析方法 锌量的测定 固液萃取分离-火焰原子吸收光谱法 2009-12-04
- YS/T 536.9-2009 铋化学分析方法 碲量的测定 砷共沉淀-示波极谱法 2009-12-04
- YS/T 536.12-2009 铋化学分析方法 镍量的测定 电热原子吸收光谱法 2009-12-04
- YS/T 536.4-2009 铋化学分析方法 银量的测定 火焰原子吸收光谱法和电热原子吸收光谱法 2009-12-04
- YS/T 536.8-2009 铋化学分析方法 氯量的测定 硫氰酸汞分光光度法 2009-12-04